User Manual

Page 40 of 57
Document Reference Phalcon-NT11, Issue 2 and Date 24/10/18
THIS IS THE PROPERTY OF Pharos Marine Automatic Power. DISCLOSURE OR REPRODUCTION IS FORBIDDEN UNLESS AUTHORISED
Registered Address: 14 Castle Mews, Hampton, England, TW12 2NP Company Reg. No. 06757705 VAT Reg. No. GB222645483
Parameter
Title
Type
Min
Max
Description
R1
NONE
1.7.5 Example
Figure 11 Setting the Morse Length to Auto Operation On and Off
1.8 Set Morse Length “MORSELEN”
1.8.1 Description
Function allows the Morse length to be configured and stored in the unit, see Table 2 Morse Length
The Morse length is set using an index that references the required length. The unit default is 7, which is equal to
22us or approx. 3.3km. This will be for the longer Morse letters e.g. “Q” and “Y” which are made up of a combination
of three dashes and one dot. However, characters such as “D” (which is made up of a dash and two dots), will be
displayed proportionately shorter because, although the individual lengths of the dashes and dots will be the same,
fewer of these will be displayed on the radar screen.
This fixed length will only be used if the unit is set to Morse Length Auto OFF.
To commit the changes to memory use the Save Configuration “SAVE” command and Get Configuration “CFGGET”
command to confirm the operation.