User Manual

Page 23 of 57
Document Reference Phalcon-NT11, Issue 2 and Date 24/10/18
THIS IS THE PROPERTY OF Pharos Marine Automatic Power. DISCLOSURE OR REPRODUCTION IS FORBIDDEN UNLESS AUTHORISED
Registered Address: 14 Castle Mews, Hampton, England, TW12 2NP Company Reg. No. 06757705 VAT Reg. No. GB222645483
Power Connector: Amphenol 62GB-12E14-19PN
Function Signal
19-Way Metal
Circular Bulkhead
Connector
POWER
BITE
BITE On - Normally Open Relay Contact (Closed if Fault A High) L
BITE Middle - Relay Contact M
BITE Off - Normally Closed Relay Contact (Open if Fault A High) A
BITE Fault Ref B
BITE Neg Fail - Opto Pulled to Fault Ref when Fault A High C
POWER +V J
POWER +V H
POWER +V G
POWER 0V K
POWER 0V T
POWER 0V S
BITE Relay Enable A (Link to Relay Enable B to enable relay) D
BITE Relay Enable B (Link to Relay Enable B to enable relay) E