Amplitude Detection
Terminal sensitivity (Firmware programmable) -50dBm min
Side lobe rejection
Automatic detection via
amplitude mapping
Frequency performance
Frequency accuracy (50ns to 200ns pulse widths) ±3.5MHz
Frequency accuracy(>200ns pulse widths) ±1.5MHz
Modulation – Plain Pulse
Morse pulse As per IALA legislation
Output Duration for Morse Letter (750 m to 8 km) 5us to 53 us
Modulation – Response to Linear Chirp Pulse
Morse Pulse Derived from IALA legislation
Output Duration for Morse Letter (750 m to 8 km) Chirp Duration + 5us to 53 us
Response Timing
Range to start position As per IALA legislation
Angular width of displayed response
Minimum angle emitter
rotates in 8 PRI or selectable
multiples of this
Firmware control functions (via terminal and RS232/USB interface)
Morse selections