Wi nd /Sol ar Hybr id Str eet Light Controll er User Manual Model: HY-WSC04-12AWM, HY-WSC04-12/24AWM, HY-WSC06-24AWM, HY-WSC06-48AWM Phaesun GmbH · Brühlweg 9 · 87700 Memmingen · Germany · Telefon +49 (8331) 990 42-12 · info@phaesun.com · www.phaesun.
1. Product Introduction The wind/solar hybrid street light controller is an intelligent apparatus which is specially designed for high-end small-scale wind/solar hybrid system and especially suitable for wind/solar hybrid street light system and wind/solar hybrid monitoring system. It can simultaneously control wind turbine and solar panel to charge battery safely and efficiently.
modes, time control output shutoff hours, light control on/off voltage points, day or night indication, load status, battery over voltage/under voltage status etc. Perfect Protection Functions: Battery over charge protection, battery over discharge protection, battery anti-reverse connection protection; load short circuit, over load protection; wind turbine current limiting, automatical brake, manual brake protection; solar anti-reverse charge, solar anti-reverse connection; lightning protection etc.
Step 4 Connect wind turbine output line to “WIND INPUT” terminals when the wind turbine is under static status or in low speed running status. If the wind turbine is single-phase DC output, just connect the positive pole line to(+) “WIND INPUT” terminal, negative pole line to (-)“WIND INPUT” terminal. Step 5 Connect solar panel positive wire to (+) “SOLAR INPUT” terminal, negative wire to (-) “SOLAR INPUT” terminal.
) Light-control and time-control symbol. It indicates light-control on and light-control off. It indicates light control on and time control off. 6)"SET" symbol indicates setting status. Parameters display symbol. Each system parameters are displayed via visual digit and graph. 7) 8)“1 2” at lower left indicates the first load output and the second load output. 9)When “ON” and a certain voltage value appear concurrently, the value is the light control on voltage point.
"Enter": Set/Confirm. In browsing window, press "Enter" to access setting window. In setting window, press this button to save parameters and return back to browsing window. "Esc": Cancel/Manual reset. In setting window, press "Esc" to return to browsing window without saving the modified parameters. In browsing window, the button is used as a manual reset key for load short circuit or over load. 4.
LCD can display three output control modes as follows: 1) Light-control on, light-control off Left picture indicates the first load output mode is controlled by sunlight intensity. The controller will automatically have output at night, automatically stop output at day with this control mode. User can adjust the light control on and light control off voltage point via LCD button or communication software.
5. Technical Data HY-WSC04- HY-WSC04- HY-WSC06- HY-WSC06- 12AWM 24AWM 24AWM 48AWM Rated Battery Voltage 12V 24V 24V 48V Rated Wind Turbine Input Power 400W 400W 600W 600W Maximum Wind Turbine Input Power 600W 600W 900W 900W Rated Solar Input Power 150W 300W 300W 300W Dumpload Voltage 13.5V 27V 29V 58V Charge Shutoff Voltage 14.5V 29V Wind Turbine Brake Current 34A 17A 25A 13A Battery Over Discharge Protection Voltage 10.8V 21.6V 21.6V 43.
6. Troubleshooting Problem The symbol flashing, no charge or discharge. Possible Cause and Solution Battery is over-voltage, check battery voltage, and whether the cables are well-connected or not, re-connect all components. Battery is over-discharge and empty. Please use the battery after it is fully charged. The symbol flashing and no output. The symbol Disconnect the battery and recover it with charger device if the battery is over discharge for a long time. flashing and no output.