User manual
25
HY-600/24V system
Distance from wind generator
to controller
0—10m 11—20m 21—30m 31—40m 41—50m 51—60m 61—70m 70—100m
AWG/Metric Wire Size
mm²
11/4 mm² 11/4 mm² 9/6 mm² 8/8 mm² 7/10 mm² 5/16 mm² 5/16 mm² 4/21 mm²
HY-600/48V system
Distance from wind generator
to controller
0—10m 11—20m 21—30m 31—40m 41—50m 51—70m 71—90m 91—110m
AWG/Metric Wire Size
mm²
11/4 mm² 11/4 mm² 11/4 mm² 11/4 mm² 10/5 mm² 8/8 mm² 8/8 mm² 7/10 mm²
HY-1000/24V system
Distance from wind generator
to controller
0—10m 11—20m 21—30m 31—40m 41—50m 51—60m 61—70m 71—90m
AWG/Metric Wire Size
mm²
10/5mm² 6/13 mm² 4/21 mm² 3/26 mm² 2/33 mm²
1/42
mm²
1/42 mm² 0/53 mm²
HY-1000/48V system
Distance from wind generator
to controller
0—10m 11—20m 21—30m 31—40m 41—50m 51—60m 61—70m 70—100m
AWG/Metric Wire Size
mm²
11/4 mm² 11/4 mm² 10/5 mm² 9/6 mm² 8/8 mm² 7/10 mm² 6/13 mm² 5/16 mm²