7. Slide front block over pressure regulator
housing.
8. Tighten front block with #8 set screws using
Loctite.
9. Cut ¼ diameter hose to desired length and
install.
10. Feed solenoid valve wires through ASA
adaptor.
11. Attach one wire to terminal TB1.
12. Attach second wire to adjacent terminal.
13. Install grip with screws supplied.
CAUTION: Be carefull not to pinch
wires between the body of the gun
and the grip frame. Use grease to
assure spring and balls are
retained in the trigger block.
14. Connect
FIRESTORM
bottom line
regulator to Autococker ASA adaptor.
Note: Customer must provide connecting
hose and hardware. I.e. fore grip, etc. PGI
recommends the use of a pressure gauge
(range to 700psi) on this kit.
15. Install 9 volt battery in grip frame.
16. Switch gun on and cycle trigger. (Selonoid
valve should be heard to “click”)
ADJUSTING
SECONDARY
REGULATOR
17. Connect barrel.
18. Connect air source.
19. Adjust primary pressure at ASA to
approximately 300psi.
20. While cycling trigger, adjust front screw on
secondary regulator until the gun begins to
cycle. Using one paintball at a time, check
velocity is at desired speed.
Note: Ball velocity is adjusted using bottom line
regulator
.