Operation Manual
Changing
the
upper
knife:
Pull
out
the
mains
plug.
For
disengageing
the
upper
knife,
see
page
29,
L
Unscrew
the
knife
retaining
screw
and
remove
upper
knife,
To
replace
the
upper
knife,
insert
the
retaining
screw
through
cutout
(1)
of
the
knife.
Screw
it
into
threaded
hole
(2)
of
the
knife
holder.
Tighten
slightly
and
set
the
upper
knife
in
the
cutting
position.
Turn
the
hand
wheel
counter-clockwise
until
the
upper
knife
is
in
its
lowest
position.
The
front
edge
of
the
upper
knife
should
be
0.5
to
1.0
mm
lower
in
this
position
than
the
surface
of
the
needle
plate.
Adjust
the
upper
knife
accurately
and tighten
the
retaining
screw
securely.