Operation Manual
HOW
TO
REPLACE
THE
STATiONARY
KNIFE
Danger:
Before
replacing
the
stationary
knife,
dis
connect
power
line
plug
from
the
wall
receptacle.
*
The
stationary
knife
should
be
changed
when
it
becomes
dull.
*
The
stationary
knife
can
be
replaced
according
to
the
directions
provided,
however
if
there
are
any
difficulties experienced,
consult
your
re
presentative
to
make
the
adjustments.
*
Be
sure
that
the
power
line
plug
is
disconnected
from
the
electric
source.
*
Open
the
looper
cover
and
set
the
movable
upper
knife
D
in
the
nonoperating
position
(page
23).
*
Loosen
the
stationary
knife
clamping
plate
set
screw
®
and
remove
the
stationary
knife
®
*
Place
a
new
stationary
knife
in
the
groove
of
the
stationary
knife
holder,
align
the
cutting
edge
level
with
the
top
surface
of
the
throat
plate
®.
*
Tighten
stationary
knife
clamping
plate
set
screw
Return
the
movable
upper
knife
CI)
to
its
operat
ing
position.
*
41