Operation Manual

Adjusting
the
machine
to
the
cover
stitch
and
two-thread
chainstitch.
Switch
off
eIectrica
power
For
cover
stitch:
Turn
the
handwheel
in
the
direction
of
the
arrow
until
the
needle(s)
is
in
the
highest
position.
Remove
the
standard
presser
foot
(see
page
22).
Detach
the
trimming
waste
container
and
open
the
looper
cover.
Disen
gage
the
upper
blade.
Set
the
bed
slide
for
the
stitch
width
latch
to
R
(see
page
25).
For
cover
stitch:
Remove
the
standard
needle
plate
by
un
screwing
screw
A
using
the
large
screwdri
ver
from
the
accessory
box.
Press
on
area
B
of
the
needle
plate.
This
raises
the
needle
plate
slightly.
Then
remove
it
to
the
left.
For
cover
stitch:
Raise
the
finger
protection
slightly
and
in
sert
cover
stitch
needle
plate
(marked
with
ā€œCā€)
from
the
accessory
box.
Re-tighten
the
screw.
Insert
cover-stitch
needle
D
and
two-thread
chainstitch
needle
C
(see
page
11).
Attach
cover-stitch
presser
foot
(marked
with
ā€œCā€)
from
the
accessory
box
(see
page
22).
I