Operation Manual
Care
and
maintenance
10.07
Checking
the
air
pressure
•
Before
each
use
of
the
machine,
check
the
air
pressure
on
gauge
1
•
The
gauge
must
display
a
pressure
of
6
bar.
•
If
necessary,
alter
the
pressure
to
this
level.
•
To
do
so,
lift
button
2
and
turn
it
so
that
the
gauge
shows
a
pressure
of
6
bar.
•
Press
button
2
back
down
again.
10.08
Emptying
I
Cleaning
the
water
container
of
the
air
filter
Turn
the
machine
off!
‘V
Remove
the
compressed-air
hose
from
the
air
filter,
Emptying
the
water
trap
•
Water
trap
1
empties
itself
automatically
when
the
compressed-air
hose
is
removed
from
the
air
filter.
Cleaning
the
filter
•
Unscrew
water
trap
1
and
filter
2.
•
Clean
the
filter
with
compressed
air
or
with
isopropyl
alcohol,
Part
number
95-665
735-91.
•
Screw
filter
2
back
in
and
water
trap
1
back
on.
1
Fig.
10-07
max.
1
Fig
10-08
10
-
5
PFAFF