Anti-Linger Prevention
The Anti-Linger Prevention feature keeps your dog from staying in the Warning Zone for
long periods of time and draining the Receiver Collar battery. Your dog will hear a warning
tone when he reaches the Warning Zone. If your dog does not return to the Pet Area after
two seconds, he will receive a continuous Static Correction until he returns to the Pet Area.
Run Through Prevention
This system includes a unique “run-through” prevention so that your dog cannot escape
the Pet Area without receiving an increased level of Static Correction. The Receiver Collar
automatically increases the Static Correction when your dog continues more than 20% of
the way through the pet fencing Boundary Width. For example, if the signal is detected 10
feet from the wire and your dog enters the Static Correction Zone, this feature is activated
when he is approximately 8 feet from the Boundary Wire. Your dog will then receive a Static
Correction that is at an increased level corresponding to the Static Correction level setting
on the Receiver Collar. The Receiver Collar is equipped to automatically increase the level of
Static Correction the longer your pet remains in the Static Correction Zone if the collar is set
at level 2 or above. The Run Through Prevention sound is an intermittent tone.
Over Correction Protection
In the unlikely event that your pet “freezes” in the Static Correction Zone, this feature
limits the static correction duration to a maximum of 30 seconds. While the system locks
out further static correction, the warning tone will continue until the pet leaves the Static
Correction Zone.
Function and Response Table
Indicator Light
Response
Static
Correction
Level
Receiver Collar Function Temperament of Pet
1 Flash 1 No Static Correction, Tone Only Initial Training Mode
2 Flashes 2 Low Static Correction Timid
3 Flashes 3 Medium Static Correction Timid or Average
4 Flashes 4 Medium High Static Correction Average or High Energy
5 Flashes 5 High Static Correction High Energy
Flashes once every
4 to 5 seconds
Indicates Low Battery
Set the Boundary Width and
Test the Receiver Collar
With the Boundary Wire in place and properly connected, it is time to set the containment
field and test the system.
The Receiver Collar should NOT be on your dog when the system is tested.
Note: The Receiver Collar is waterproof, which can make the tone hard to hear.
The flashing Test Light when held to the Contact Points indicates the Receiver Collar is
delivering Static Correction. To best utilize the automatic Run-Through Prevention feature,
the containment Boundary Width should extend at least 6 to 10 feet on each side of the
Boundary Wire (total Boundary Width of 12 to 20 feet).
1. Apply Power to the Fence Transmitter with the supplied Power Adapter.
2. The width of the containment field is adjusted using the transmitter’s Boundary Width
Control knob. Turn the knob counter clockwise until the Loop Indicator Light is no
longer lit. Turn the knob clockwise and increase by 2 numbers. The light should turn ON.
The Receiver Collar should not be on your dog when the system is tested.
Your pet may receive an unintended correction.
Step