Instructions / Assembly
14 1-800-732-2677
Function and Response Table
Indicator Light
Response
Static Correction
Level
Receiver Collar Function Temperament of Pet
1 Flash 1 No Static Correction, Tone Plus Vibration Initial Training Mode
2 Flashes 2 Low Static Correction Timid
3 Flashes 3 Medium Static Correction Timid or Average
4 Flashes 4 Medium High Static Correction Average or High Energy
5 Flashes 5 High Static Correction High Energy
Flashes once every
4 to 5 seconds
Indicates Low Battery
Set the Boundary Width and Test the Receiver Collar
With the Boundary Wire in place and properly connected, it is time to set the containment
field and test the system.
CAUTION
The Receiver Collar should NOT be on your dog when the system is tested.
Note: The Receiver Collar is waterproof, which can make the tone hard to hear.
The flashing Test Light when held to the Contact Points indicates the Receiver Collar is
delivering Static Correction. To best utilize the automatic Run-Through Prevention feature,
the containment Boundary Width should extend at least 6 to 10 feet on each side of the
Boundary Wire (total Boundary Width of 12 to 20 feet).
6A
1. Apply Power to the Fence Transmitter with the supplied Power Adapter.
2. Set the Boundary Width Control Switch (located on the side of the
Fence Transmitter)
(6A)
to the A, B, or C setting based on the total
length of Boundary Wire used.
Setting B is used for most properties.
The
table to the right will indicate the proper setting.
3. The width of the containment field is adjusted using the transmitter’s
Amount of Wire Setting
Greater than 2400 feet A
Up to 1300 feet B
1300 to 2400 feet C
Boundary Width Control knob. Turn the knob counterclockwise until the alarm sounds and the Loop
Indicator Light is no longer lit. Turn the knob clockwise and increase by 2 numbers. The alarm should turn
OFF and the Loop Indicator Light should turn ON.
CAUTION
The Receiver Collar should not be on your dog when the system is tested. Your pet may receive an unintended correction.
4. Place battery in Receiver Collar. To identify the Warning and Static Correction Zones make sure the
Receiver Collar is set at level 5 (see Step 5).
Step
6