operators_manual
Table Of Contents
WHATTODOIF...
FuseInspectionandReplacement
Alltheelectricalcircuitshavefuses
toprotectthemfromashortcircuitor
overload.Ifsomethingelectricalon
yourchassisstopsworking,therst
thingyoushouldcheckforisablown
fuse.
1.TurnOFFalllightsandaccessories
andremovetheignitionkeyto
avoiddamagingtheelectrical
system.
2.Determinefromthechartonthe
fusepanelwhichfusecontrolsthat
component.
3.Removethatfuseandseeifitis
blown.
1Blown
Ifitisblown,replaceitwithafuseof
thesamerating.
Ifafuseofthesameratingisnot
available,afuseofalowerratingmay
betemporarilysubstituted.Youcan
alsouseafusefromacircuityoucan
dotemporarilywithout(forexamplean
accessorycircuitorradio).
CAUTION
Whenreplacingafailedcircuit
breaker,alwaysuseanapproved
circuitbreakerwithacurrentrat-
ingequaltoorlessthanthecircuit
breakerbeingreplaced.Onlyuse
theapprovedTypeIImodiedre-
setcircuitbreakers.NEVERuse
aTypeI(automaticreset)orType
III(manualreset)circuitbreaker.A
fusewithacurrentratingequaltoor
lessthanthecircuitbreakerbeing
replacedcanalsobeused.
2-10Y53-6076-1B1(03/17)
2