operators_manual

Table Of Contents
Cranking Battery Specification
Category Specification
Group 31
Stud Type Threaded
Cold Crank Amps 650
Voltage 12 V
Reserve Capacity 160 minutes
General Maintenance free
Removing Batteries
After accessing the batteries, follow these
steps to remove them from the vehicle.
CAUTION
Wait at least 10 minutes after the key
switch
is turned OFF before discon-
necting battery power. The system
uses battery power to circulate DEF
and prevent overheating of the DEF
system. Failure to comply may result
in property damage.
1. Be sure all switches on the vehicle
are turned OFF
2.
Wait 10 minutes after turning
ignition off before disconnecting the
batteries
3. Disconnect negative (-) ground
cable first
4. Disconnect positive (+) cable
5. Unscrew the holding plate bolts
with an open end wrench
NOTE
Always dispose of automotive batter-
ies
in a safe and responsible manner.
Contact your authorized dealer for dis-
posal standards. Call your local au-
thorized recycling center for informa-
tion on recycling automotive batteries.
Follow the procedures below to reinstall
batteries on the vehicle and replace parts
removed for access.
Installing Batteries
Follow the procedure below to reinstall
main batteries on the vehicle:
NOTE
Always dispose of automotive batter-
ies
in a safe and responsible manner.
Contact your authorized dealer for dis-
posal standards. Call your local au-
thorized recycling center for informa-
tion on recycling automotive batteries.
NOTE
Make sure to reconnect the ground
(negative) cable last.
WARNING
Battery replacement may alter or dis-
turb battery cable routing. Check to in-
sure battery cables are free from any
point of chaffing. Failure to comply
may result in death, personal injury,
equipment or property damage.
1. Place batteries in vehicle and
tighten bolt of holding plate
2. Reconnect positive cable
MAINTENANCE - Electrical System