Operations Guide

14
number of reference tags. The clock at the bottom displays the elapsed time since the
reader was started.
2.2 Compliance with ETSI Guidelines for Human Exposure
to Radio Frequency Electromagnetic Fields
European Council Recommendation 1999/519/EC details basic restrictions and
reference levels on human exposure to electromagnetic fields as advised by the
ICNIRP and states that adherence to these recommended restrictions and reference
levels should provide a high level of protection as regards the established health
effects that may result from exposure to such fields.
By the very nature of the RFID DAS 9200 reader system design and installation for
correct operation, users should not find themselves within close proximity of the
antennas. EN 62311:2008 is the applicable Harmonised Standard for EM fields
generated by this RFID DAS 9200 system and all installations comply with this
standard and the recommendations, and are safe when antennas are installed such
that:
(a) A minimum antenna separation of 0.25m is maintained
and
(b) An individual can be no nearer than 0.25m from an antenna for a period of 6
minutes at any one time.
These guidelines are based on the Maximum Permissible Exposure (MPE) Calculation
Report generated by UL. Please get in touch with PervasID should you wish you see
the report [4].
Warning: We strongly recommend that users must follow above guidelines. Under no
circumstances should the RFID DAS 9200 be installed and operated outside these
specifications.