SDS

Material Safety Data Sheet
1. PRODUCT IDENTIFICATION
Product Name: 84115 5 MINUTE PLASTIC WELD (ACTIVATOR)
Item No: PTX203012B
Product Type: Activator
2. COMPOSITION/INFORMATION ON INGREDIENTS
Component: Weight% ACGIH; TLV-TWA OSHA PEL
METHYL METHACRYLATE
80-62-6
60-80 50 ppm 100 ppm; 410 mg/m
3
ACRYLONITRILE-BUTADIENE
POLYMER
9003-18-3
1-10 Not listed Not listed
3,5-DIETHYL-1,2-DIHYDRO-1-
PHENYL-2-PROPYLPYRIDINE
34562-31-7
1-10 Not listed Not listed
3. HAZARDS IDENTIFICATION
Toxicity:
May cause eye and skin irritation. May cause skin sensitization. Exposure to vapors or mist may result in
irritation of the respiratory tract.
Primary Routes of Entry:
Eye and skin contact, ingestion, inhalation
Signs and Symptoms of Exposure:
Eyes: Exposure to liquid or vapor causes moderate eye irritation. Symptoms may include burning, tearing,
redness, stinging, blurred vision and corneal injury. Repeated skin contact may cause allergic skin
reactions. Excessive accidental exposure may cause headache, dizziness, nausea and mild respiratory
irritation. Moderately toxic if swallowed. Irritating to mouth, throat and stomach with nausea.
Component: Weight% NTP ACGIH Carcinogens IARC Carcinogen
METHYL METHACRYLATE
80-62-6
60-80 male rat-no evidence;
female rat-no
evidence; male mice-
no evidence; female
mice-no evidence
A4 - Not Classifiable
as a Human
Carcinogen
Group 3: Monograph 60, 1994
Aggravated Medical Condition:
Preexisting eye, skin and respiratory disorders may be aggravated by overexposure to this product.
4. FIRST AID MEASURES
Ingestion:
If swallowed, do not induce vomiting - seek medical advice. Never give anything by mouth to an
unconscious person.
Inhalation:
Move to fresh air in case of accidental inhalation of vapors. Obtain medical attention.
Skin Contact:
Remove contaminated clothing. Wash area with soap and water. If irritation persists, seek medical
attention
Eye Contact:
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes and get medical
attention if irritation persists
5. FIRE FIGHTING MEASURES
Flash Point °F(C°):
52.7°F (11.5°C)
Recommended Extinguishing Media:
Carbon dioxide, Dry chemical, Foam
Special Fire-Fighting Procedures:
Firefighters shoud wear self-contained breathing apparatus and protective
clothing to prevent all skin and eye contact
Hazardous Products of Combustion:
Oxides of carbon, Oxides of nitrogen
Unusual Fire/Explosion Hazards:
Flammable. Closed containers may rupture or explode when exposed to
extreme heat.
Lower Explosive Limit:
1.6%
Upper Explosive Limit:
12.5%