SDS
_____________________________________________________________________________________________
80208 - 767 ANTI-SEIZE LUBRICANT 1LB Revision Date 11-May-2020
Prevention of secondary hazards
Clean contaminated objects and areas thoroughly observing environmental regulations.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Use with local exhaust ventilation. All equipment used when handling the product must be
grounded. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use
personal protective equipment as required. Do not breathe
dust/fume/gas/mist/vapors/spray. Take necessary action to avoid static electricity discharge
(which might cause ignition of organic vapors).
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a cool, well-ventilated place. Keep away from heat. Keep
in properly labeled containers.
Incompatible materials
Strong oxidizing agents, Acids, Alkalis, Amines
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
.
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
CALCIUM OXIDE
1305-78-8
TWA: 2 mg/m
3
TWA: 5 mg/m
3
(vacated) TWA: 5 mg/m
3
not in
effect as a result of reconsideration
IDLH: 25 mg/m
3
TWA: 2 mg/m
3
GRAPHITE
7782-42-5
TWA: 2 mg/m
3
respirable
particulate matter all forms except
graphite fibers
TWA: 15 mg/m
3
total dust
synthetic
TWA: 5 mg/m
3
respirable fraction
synthetic
(vacated) TWA: 2.5 mg/m
3
respirable dust natural
(vacated) TWA: 10 mg/m
3
total
dust synthetic
(vacated) TWA: 5 mg/m
3
respirable
fraction synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m
3
TWA: 2.5 mg/m
3
natural respirable
dust
ALUMINIUM POWDER
7429-90-5
TWA: 1 mg/m
3
respirable
particulate matter
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable
fraction (vacated) TWA: 5 mg/m
3
Al
Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
TWA: 5 mg/m
3
Al
NIOSH IDLH Immediately Dangerous to Life or Health
Other Information
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992).
Appropriate engineering controls
Engineering Controls
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/face protection
Tight sealing safety goggles.
Skin and body protection
Wear protective natural rubber, nitrile rubber, Neoprene⢠or PVC gloves.
Respiratory protection
Use NIOSH-approved air-purifying respirator with organic vapor cartridge or canister, as
_____________________________________________________________________________________________