PRODUCT DESCRIPTION S.I.N.: 834-300
Permatex
Cold Weld Bonding Compound is a two-part, very
fast curing, high strength, general purpose adhesive and filler
system. It repairs, fills and bonds to iron, steel, brass, bronze,
aluminum and copper. Once this materials is cured, it can be
drilled, tapped, threaded, filed and painted.
PRODUCT BENEFITS
Easy To Use:
No heating required
Fast and Reliable:
Holds in 10- 15 minutes
Useable in 30 minutes
Good moisture resistance
Withstands extreme temperatures
Safe To Use:
Non-flammable
TYPICAL APPLICATIONS
Cracked transmission cases
Chipped heads
Rear end castings
Cracked blocks
Cracked intake manifolds
Damaged keyways
Split stampings
DIRECTIONS FOR USE
1. Before starting, make sure your work area is protected
from accidental spills. Surfaces must be clean, dry
and free of grease and oil.
2. Roughen smooth surfaces to be repaired with
sandpaper.
3. Apply in ventilated area. Vapors may irritate eyes and
nose.
4. Squeeze out equal amounts of bonding agent and
curing agent.
5. Mix together thoroughly until color is uniform.
6. Apply immediately to both surfaces and press
together. Remove excess glue at once.
7. Allow bond to set for 10 minutes before moving.
8. After 16 hours, typical shear strength on steel is 3000
PSI.
9. Curing time may be slower in cold weather.
For Cleanup
1. Cleanup must be completed before curing is
complete. Use acetone or mineral spirits for cleanup.
2. Clean hands with Permatex
brand hand cleaners.
PROPERTIES OF UNCURED MATERIAL
Typical Value
Chemical Type Epoxy, amine resins
Appearance Resin – black
Hardener - beige
Odor Mild
Specific Gravity (mixed) 1.79
Flash Point, TOC, °F >400
TYPICAL CURING PERFORMANCE
Permatex
Cold Weld Bonding Compound has a gel time of 4
to 6 minutes, fixture time of 10 to 15 minutes with a full cure in
16 hours.
TYPICAL ENVIRONMENTAL RESISTANCE
Temperature Resistance
Typical Values
Continuous, °C (°F) Maximum 149(300)
Intermittent, °C (°F) Maximum 177(350)
Chemical / Solvent Resistance
The product retains effective properties when in contact with
water, oil, fuels and solvents.
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
an adhesive for chlorine or other strong oxidizing
materials.
For safe handling information on this product, consult the
Material Safety Data Sheet, (MSDS).
ORDERING INFORMATION
Part Number Container Size
14600 2-1 oz. tubes, carded
STORAGE
Products shall be ideally stored in a cool, dry location in
unopened containers at a temperature between 8°
to 28°C
(46°
to 82°F) unless otherwise labeled. Optimal storage is at
the lower half of this temperature range. To prevent
contamination of unused product, do not return any material to
its original container.
NOTE
The data contained herein are furnished for information only
and are believed to be reliable. We cannot assume
responsibility for the results obtained by others over whose
methods we have no control. Permatex, Inc. specifically
disclaims all warranties expressed or implied, including
warranties of merchantability or fitness for a particular
purpose, arising from sale or use of Permatex, inc.
products and disclaims any liability for consequential or
incidental damages of any kind, including lost profits.
This product may be covered by one or more United States or
foreign patents or patent applications.