10. STABILITY AND REACTIVITY
Chemical stability: Stable in dry environments.
Conditions to avoid: Contact with strong acids
Incompatibility: None
Hazardous decomposition: None known
Hazardous polymerization: Will not occur.
11. TOXICOLOGICAL INFORMATION
Human Data
There is no information on toxicokinetics, metabolism and distribution.
There have been reports of irritation and burns to mucus membranes of the eyes and respiratory tract
upon acute exposure to dusts in excess of the recommended limits.
Chronic exposure to crystalline silica (a naturally occurring contaminant) in the respirable size has been
shown to cause silicosis, a debilitating lung disease. In addition, the International Agency for Research on
Cancer (IARC) classifies crystalline silica inhaled in the form of quartz or cristobalite from occupational
sources as carcinogenic to humans, Group 1. The National Toxicology Program (NTP) classifies
respirable crystalline silica as a substance which may be reasonably anticipated to be a carcinogen.
OSHA does not regulate crystalline silica as a human carcinogen. Industrial hygiene monitoring to date
has not identified any detectable respirable crystalline silica in dust sampling conducted during gypsum
panel installation utilizing recommended procedures.
Animal Data
LD
50
and LC
50
data not available.
12. ECOLOGICAL INFORMATION
This product could be toxic to fish due to its high alkalinity from the portland cement. No studies are
available.
13. DISPOSAL CONSIDERATIONS
Dispose of according to Local, State, Federal, and Provincial Environmental Regulations.
Recycle if possible.
14. TRANSPORT iNFORMATION
This product is not a DOT hazardous material
Shipping Name: Same as product name
ICAO/IATA/IMO: Not applicable
15. REGULATORY INFORMATION
All ingredients are included on the TSCA inventory.
Federal Regulations
SARA Title III: Not listed under Sections 302, 304, and 313
CERCLA: Not listed
RCRA: Not listed
OSHA: Dust and potential respirable crystalline silica generated during product use may be hazardous.