Faucet Installation

PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
8
perlick.com
CONNECTING THE REGULATOR TO THE
CO2 CYLINDER
1. Remove the blue plug from the regulator tting, but do
not remove the carbonic washer.
2. Screw regulator onto gas cylinder valve. Tighten with
wrench until vertically straight. Be sure that the shut-o
valve on the regulator is in the OFF (horizontal) position.
3. Place screw clamp over the end of red line and push onto
regulator tail piece. Tighten clamp with a screwdriver.
4. Turn regulator adjusting screw counterclockwise until
it turns freely.
5. Turn hand valve counter-clockwise on the CO2 cylinder
to the fully open position.
6. Turn regulator adjusting screw clockwise until desired
pressure is reached (approximately 12-15 lbs.) Tighten
stop nut on adjusting screw.
7. Open shut-out valve on bottom of regulator.
CO2 LEAK TEST
Dilute a small amount of liquid dishwashing soap and rub
the soapy mixture around each connection. If bubbles
appear, tighten the connection.