Service Manual

Column Refrigeration Service Manual
Return to Table of Contents
44
STEP 1 - Door Gaskets
Check door gaskets for rips, cracks, or other
damage.
Thedoorgasketshouldbepushedinrmlyandlay
at.
Ensure gasket forms a complete seal around the
door.
6.0 Refrigeration System Repair
6.1 Air Inltration
Airinltrationcanoccurinseverallocations.
NOTE: Unit may manifest longer than normal
run times caused by the additional loads that air
inltrationpresents.
Signsofairinltrationinclude:
Presence of water, moisture or ice
Condensation on glass or metal surfaces
STEP 2 - Sealing Compound
Sealing compound is used to seal wiring and line
set pass-through between the condenser and the
evaporator compartments.
See Figure 6-1.1 and
6-1.2.
Additionally, sealing compound is used to seal door
switch wiring pass-through holes at top of cabinet.
See Figure 6-1.3 and 6-1.4.
Check for voids and ensure sealing compound
completelyllsspace(bothoninteriorandexterior
openings (if both tubes and wires pass-through and
opening, ensure sealing compound is used between
the items).
Figure 6-1.1. Sealing Compound (Inside)
Figure 6-1.2. Sealing Compound (Outside)
Figure 6-1.3. Sealing Compound - Door Switch (Inside)
Figure 6-1.4. Sealing Compound - Door Switch (Outside)