Service Guide

Column Refrigeration Service Manual
Return to Table of Contents
48
6.4 Condenser Coil Cleaning
Perlick’s warranty does not cover cleaning of
the condenser coil.
The condenser coil should be free obstruction,
dust and debris. The condenser coil should be
cleaned every 6 months or more or less often
dependent upon the environment.
To clean the condenser:
1. Open the door and remove the grill by pulling
away from the cabinet (grill is held on by four
(4) latch and mate connectors).
See Figure
6-7.1.
2. Once the grill is removed, using a soft brush
and vacuum, remove any dust or debris, being
carefultoavoiddamaging(bending)thenson
the condenser coil.
See Figure 6-7.2.
3. Once cleaned, reinstall the grill.
Figure 6-7.1. Remove Grill
Figure 6-7.2. Clean Condenser Coil
Condenser Coil