Instruction Manual

FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3
Form No. Z2295
Rev. 11.19.2020
JOB
AREA
ITEM NO.
MODEL NO.
BC24 SERIES
BC36 SERIES
BC48 SERIES
BC60 SERIES
BC72 SERIES
BC96 SERIES
C
US
BC72 shown
BC24 shown
R290
Refrigerant
MODEL NUMBERS BC24 BC36 BC48 BC60 BC72 BC96
EXTERIOR CABINET
DIMENSIONS
Length - in. (mm) 24 (610) 36 (914) 48 (1219) 60 (1524) 72 (1829) 96 (2436)
Depth - in. (mm) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610)
Height - in. (mm) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866)
INERNAL NET VOLUME - cubic ft. (liters) 4.2 (118) 8.6 (242) 12.5 (353) 16.3 (462) 20.3 (575) 28.3 (800)
CASE CAPACITY (12 bottles) 5.5 9.8 17.2 21.0 28.3 41.0
CASE CAPACITY (12 cans) 7 16 25 30 36 58
SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235)
CABINET CONSTRUCTION (INTERIOR) All models have stainless steel walls and oor.
CABINET CONSTRUCTION (EXTERIOR)
Choice of black, stainless steel and all stainless.
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized.
Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized.
All Stainless Option: Front, ends, back and bottom are all stainless steel.
DOORS AND HARDWARE Sliding style open with standard locks. Stainless steel top and bottom panss. Die cast handle
PLUMBING No drain required. Condensate evaporates automatically.
INSULATION 2 inch foamed-in-place, environmentally friendly Ecomate® polyurethane insulation. Blowing agent R-611.
VENTILATION
2’ model is front vented, all other models require 2” clearance from wall on either left end or back of cabinet for proper
air ow.
TEMPERATURE
SPECIFICATIONS
Default Temperature Setpoint:
Standard Temp (RT) Models - °F [°C]
38 [3.3]
Adjustable Setpoint Range:
Standard Temp (RT) Models - °F [°C]
34 - 40 [1.1 - 4.4]
Default Temperature Setpoint:
Low Temp (LT) Models - °F [°C]
30 [-1.1]
Adjustable Setpoint Range:
Low Temp (LT) Models - °F [°C]
28 - 34 [-2.2 - 1.1]
Default Temperature Setpoint:
Wine Temp (WT) Models - °F [°C]
50 [10.0]
Adjustable Setpoint Range:
Wine Temp (WT) Models - °F [°C]
45 - 60 [7.2 - 15.6]
ELECTRICAL
SPECIFICATIONS
Supply 120 VAC/60 Hz/1 Ph
Running Load Amps 1.9 1.9 3.1 4.4 4.4 4.4
Power Cord 6-foot length with NEMA 5-15 plug.
Thermostat NSF Listed electronic control.
Defrost Type Automatic electric defrost (Low Temp models only).
Lighting Type LED (136 Lumens, 5500K)
REFRIGERATION
SPECIFICATIONS
Condensing Unit Hermetic condensing unit pulls out for service and cleaning.
Expansion Device Capillary Tube
Refrigerant R290
Refrigerant Charge (g) 90 110 120 120 120 120
Compressor H.P. 1/6 1/6 1/5 1/4 1/4 1/4
Total Heat of Rejection
At 75°F ambient (BTU/h)
1420 1420 1920 2980 2980 2980
OPTIONAL ACCESSORIES
Floor racks • Casters • Bottle opener and receiver • Bin dividers
Speed rails • Adjustable legs • Roller basket shelving
*