Install Guide

Drain Pump Kit for Undercounter Clear Ice Maker
For use with H50IM Series Clear Ice Makers
Form No. Z2334A, 02/25/2013
Check to ensure all parts are included:
Index
No. Description Qty.
1 Drain Pump Assembly 1
2 Vinyl Hose (drain hose) (5/8” ID x 6.5”) 1
3 Vinyl Hose (drain hose) (3/8” ID x 27.5”) 1
4 High Pressure Clear PVC Hose (discharge hose) (1/2” I.D.× 10’) 1
5 Small Clamp (vent hose to drain pump) 1
6 Medium Clamp (discharge hose to drain pump) 1
7 Large Clamp (drain hose/drain elbox to ice maker and drain pump) 2
8 Hose Clips (vent hose) 2
8a Truss Head Screw (4×8, SS) 2
Perlick Drain Pump
Catalog No. 63802A (Part No. HS-5061)
• Only qualied service technicians should install and service this drain pump to reduce the risk of death, electric shock,
serious injury or re. A plumbing permit and the services of a licensed plumber may be required in some areas.
• No installation or service should be undertaken until the technician has thoroughly read these instructions. Failure to
install, prime, operate, and maintain this drain pump in accordance with these instructions will adversely aect safety,
performance, component life, and warranty coverage and may result in costly water damage.
• Proper installation is the repsonsibility of the installer. Product failure or property damage due to improper installation is
not covered under the warranty.
• See the instruction manual provided with the icemaker for icemaker installation. Failure to install the icemaker within
these guidelines many adversely aect safety, performance, component life, and warranty coverage.
• Clean, sanitize and maintain the icemaker per the instructions provided in the icemakers instruction manual. If the
instruction manual is not available, consult with your local distributor or call Perlick Technical Service Support at (800)
558-5592 in the USA.
• THE ICEMAKER MUST BE GROUNDED: The icemaker is equipped with a 3-prong grounding plug to reduce the risk of
potential shock hazards. It must be plugged into a properly grounded, independent 3-prong wall outlet. If the outlet
is a 2-prong outlet, it is your personal responsibility to have a qualied electrician replace it with a properly grounded,
independent 3-prong wall outlet. Do not remove the ground plug from the power cord and do not use an adapter plug.
• The icemaker and this kit must be installed in accordance with applicable national, state, and local codes and
regulations.
• Protect the oor when moving the icemaker to prevent damage to the oor.
• This drain pump is approved for use only with the models listed.
WARNING
1

Summary of content (8 pages)