Installation guide
 Perle 10/100/1000 Ethernet Extended Temperature Media Converter 
 Installation Guide
10
Installing the Simplex Fiber Cable 
1.  Locate a 1000Base-X compliant simplex (1 strand) fiber cable 
with appropriate connectors. Ensure that the TX wavelength 
matches the RX wavelength at the other end and the RX 
wavelength matches the TX wavelength at the other end. 
2.  Connect the fiber cable from one media converter to the other 
media converter/switch/fiber device. 
Installing the Copper Cable 
1.  Locate 10/100/1000Base-T compliant copper cables with the 
appropriate connectors. 
2.  Connect the RJ-45 cable between the Perle media converter 
and the device. 
Note: The Perle media converter supports Auto-MDIX which 
allows connection of a straight-through or cross-over Ethernet 
cable. See Auto-MDIX Jumper Settings in this guide for jumper 
positions. 
Grounding the Media Converter 
If your installation requires additional grounding this procedure can 
be followed. 
Grounding the chassis requires the following items: 
•  One grounding lug (not provided). 
•  Grounding wire 12 to 18 AWG (not provided). 
•  Cross-head screwdriver (not provided). 
Note: For your safety, when installing this equipment, always 
ensure that the chassis ground connection is installed first and 
disconnected last. 