Installation guide
- 14 - IDS-108F Installation Guide
Technical Specifications
Connection
Dual input terminal block power
8 port Ethernet
Power Input/Consumption
9.6 to 60 VDC, 0.
5A max
18 to 30 VAC, 0.
25A max
Dual input terminal block power
8+1 fiber port
Power Input/Consumption
9.6 to 60 VDC, 0.
7A max
18 to 30 VAC, 0.
35A max
Dual input terminal block power
8 + 2 fiber ports
Power Input/Consumption
9.6 to 60 VDC, 0.
9A max
18 to 30 VAC, 0.
45A max
Reverse Polarity Protection Yes
Interface
RJ-45 10/100Base-TX
, auto negotiation speed F/H
duplex mode and auto MDI/MDI-X
Fiber Ports One or two SC/ST fiber ports
LED indicators P1 – power 1
P2 – power 2
Ports 1 – 8 G/Y – Link/Activity/Speed
Port 9 – port status (Fiber models only)
Port 10 – port status (Fiber models only)
Environmental
Operating Temperature
Commercial Models
Industrial Models
0°C to 60°C (32°F to 140°F)
-40°C to 75°C (-40°F to 167°F)
Storage Temperature
Commercial Models
Industrial Models
-25°C to 70°C (-13°F to 158°F)
-40°C C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 90% non-condensing
Storage Humidity 5% to 95% non-condensing
Operating Altitude Up to 3,048 m (10,000 ft)
Regulatory Approvals
Safety cUL 60950-1, EN 60950-1
Industrial UL 508
Hazardous Locations ANSI/ISA 12.12.01-20xx Class I Division 2
Groups A-D - Pending
ATEX Class I Zone 2 - Pending
Laser Safety Transmitters: EN60825-
1:2007 FDA/CDRH
21 CFR1040.11/CFR1040.11
EMI/EMC FCC Part 15 – Class B
CISPR22 / EN55022 Class B
EN55024 Class B