Installation guide

- 18 - IDS-105G Installation Guide
IDS-105G-S2SC40 SC None
SM
duplex
40 km
24.9 miles
TX: 1310
RX:1310
Min:-3
Max:-5
Min:-23
Max:-3
20
IDS-105G-S2ST40 ST None
SM
duplex
40 km
24.9 miles
TX: 1310
RX:1310
Min:-3
Max:-5
Min:-23
Max:-3
20
IDS-105G-S1SC40U SC None
SM
duplex
40 km
24.9 miles
TX: 1310
RX:1490
Min:-3
Max:-2
Min:-23
Max:-3
20
IDS-105G-S1SC40D SC None
SM
duplex
40 km
24.9 miles
TX: 1490
RX:1310
Min:-3
Max:-2
Min:-23
Max:-3
20
IDS-105G-S2SC70 SC None
SM
duplex
70 km
43.5 miles
TX: 1550
RX:1550
Min:-2
Max:5
Min:-23
Max:-3
21
IDS-105G-S2ST70 ST None
SM
duplex
70 km
43.5 miles
TX: 1550
RX:1550
Min:-2
Max:5
Min:-23
Max:-3
21
IDS-105G-S1SC80U ST None
SM
simplex
80 km
49.7 miles
TX: 1510
RX:1590
Min:-2
Max:3
Min:-26
Max:-3
24
IDS-105G-S1ST80D ST None
SM
simplex
80 km
49.7 miles
TX: 1590
RX:1510
Min:-2
Max:3
Min:-26
Max:-3
24
IDS-105G-S2SC120 SC None
SM
duplex
120 km
74.6 miles
TX: 1550
RX:1550
Min:0
Max:5
Min:-32
Max:-9
32
IDS-105G-S1SC120U SC None
SM
simplex
120 km
74.6 miles
TX: 1510
RX:1590
Min:-2
Max:3
Min:-26
Max:-3
24
IDS-105G-S1SC120D ST None
SM
simplex
120 km
74.6 miles
TX: 1590
RX:1510
Min:-2
Max:3
Min:-26
Max:-3
24
IDS-105G-S2SC160 SC None
SM
duplex
160 km
100 miles
TX: 1550
RX:1550
Min:0
Max:5
Min:-32
Max:-9
32
IDS-105G-S2ST160 ST None
SM
duplex
160 km
100 miles
TX: 1550
RX:1550
Min:0
Max:5
Min:-32
Max:-9
32
* fiber characteristics are determined by the SFP inserted