Perle IDS-105F (XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500338-10 (Rev B)
Overview This document contains instructions necessary for the installation and operation of the Perle IDS-105F Ethernet switch. This Ethernet switch can be ordered as a 5-port RJ-45 switch or with 4 RJ-45 ports and one SC or ST fiber port. The fiber port can be either single mode (SM) or multimode (MM) depending on the model selected and they can operate over different wavelengths and distances. Visit the Perle website for the most up to date installation guides, models and specifications. http://www.
Getting to know your IDS-105F Switch Package Contents: • • • IDS-105F DIN-rail mounting clip (pre-installed on the unit) This guide Note – Optional panel/wall mounting kits may be ordered Front View of IDS-105F (5 port RJ-45) 105F Installation Guide -3-
Front View of IDS-105F (with one fiber port) Top view of the IDS-105F -4- 105F Installation Guide
Power The IDS-105F switch has two power inputs that can be connected simultaneously to DC or AC power sources. See Top view of the IDS-105F for location. If one power source fails, the other acts as a backup, and automatically powers the switch. See Connecting Power to the IDS-105F for information on how to connect power. Reset Button To reset the IDS-105F insert a paper clip into the air hole vent (see Top view of the IDS-105F for location) and gently press the reset button.
Dimensions for the IDS-105F -6- 105F Installation Guide
105F Installation Guide -7-
Mounting the IDS-105F on a DIN-rail 1. The DIN-rail clip will be fixed to the back panel of the IDS105F switch when you receive the product. 2. Position the IDS-105F such that the top of the DIN-rail fits into the slot on the top of the DIN-rail clip, just below the hook and behind the spring. 3. While pushing down on the unit to compress the spring rotate the bottom of the IDS-105F toward the rail. This will snap the bottom of the rail into the bottom of the clip.
Wall/Panel Mounting Note: the dimensions are in mm 105F Installation Guide -9-
Wall Mounting the IDS-105F 1. Remove the DIN-rail clip from the rear panel on the IDS-105F. 2. Attach the wall mount plates to the IDS-105F as shown below using the screws provided in the kit. 3. Use the wall mount plates as a guide to mark the spots where the screws will be. 4. Drive the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws. 5.
Wiring up the IDS-105F Power sources must be off prior to beginning the power connection steps. Ensure that the voltage and current ratings of the intended power source are appropriate for the IDS105F as indicated on the product label. Ensure that the installation and electrical wiring of the equipment is performed by trained and qualified personnel and that the installation complies with all local and national electrical codes.
Grounding the chassis requires the following items: • One grounding lug (not provided) • One 18-12 AWG wire (not provided) Connecting Power to the IDS-105F 1. Ensure the power source is off prior to connection. th 2. Strip both wires 5mm (3/16 inch). 3. Loosen the terminal block screws for P1 and connect positive (+) and negative (-) wires into the -/+ terminals. 4. Tighten terminals screws (0.22Nm-0.25Nm torque). 5. Ensure the wires are securely fastened. 6.
8-pin RJ-45 Remaining pins not used. Fiber Port Cabling Requirements MM: 50/125 microns or 62.5/125 microns SM: 9/125 microns Connect the fiber cable to Port 5 on the IDS-105F and the other end to a compliant fiber device. If you are making your own fiber cables, remember that the RX on one side needs to go to TX on the other side and vice versa. See diagram below.
Technical Specifications Connection Dual input terminal block power Power Input/Consumption 9.6 to 60 VDC, 0.37A max 18 to 30 VAC, 0.
IDS-105F models Fiber Connector Mode Distance Wavelength (nm) TX Power (dB) RX Power (dB) Budget Fiber Specifications IDS-105F (XT) None n/a n/a n/a n/a n/a n/a IDS-105F-M2SC2 (XT) SC MM duplex 2 km 1.2 miles TX: 1310 RX:1310 Min:-6 Max:-0 Min:-17 Max:-0 11 IDS-105F-M2ST2 (XT) ST MM duplex 2 km 1.2 miles TX: 1310 RX:1310 Min:-6 Max:-0 Min:-17 Max:-0 11 IDS-105F-M1SC2U SC MM duplex 2 km 1.
Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Warranty / Registration http://www.perle.com/support_services//warranty.shtml Copyright © 2014 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited.