Installing Protocol Transparent Media
Converter Modules
Caution: Observe electrostatic discharge precautions when
installing the Protocol Transparent Media Converter module(s) into
the chassis. Failure to observe this caution could result in damage
to the module(s) and/or chassis.
The Protocol Transparent Media Converter module(s) can be
installed in any available slot and in any order within the MCR1900
chassis.
1. Remove the module from its packaging.
2. Using a cross-head screwdriver, remove the screw holding the
face plate to the chassis to reveal the slot opening.
3. Set the jumper and DIP switches on the module to the
desired operating mode. (optional)
4. Locate the top and bottom alignment guides inside the MCR
chassis.
5. Using the module alignment guides gently slide the module
into the slot until it becomes flush with the front of the chassis.
Light pressure may be needed to seat the module. Do not
force the module as you might cause damage. If there is
resistance, remove the module and check the module
connector for damaged or incorrectly aligned pins. If these are
not damaged, retry module insertion.
6. Tighten the captive retainer screw to ensure the module is
locked in place.
7. Remove the dust cap from the fiber connectors.