Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

Hardware and Connectivity 49
Powering Up the IOLAN
1. For terminal# 1 through 8, the use of ring terminals size #6 (M3.5) is recommended using stranded wire size AWG
18-14. Tighten all screws to a torque of 12 Lb-in (1.36 Nm).
2. For terminal# E, the use of ring terminal size #8 (M4) is recommended using stranded wire size AWG 18-14. Tighten
screw to a torque of 12 Lb-in (1.36 Nm).
3. Use the “Chassis Ground” terminal connection for grounding the unit. “Earth Ground” should be used as secondary
grounding source only.
4. Be sure to replace the clear plastic electrical safety shield before applying power to the unit.
Wiring up a the Fail-Safe Relay
The Electric Utility series of IOLAN units are also fashioned with a Fail-Safe Relay. The relay is engaged
after the unit is powered up and the software has loaded properly. Should a failure occur, the relay will be
disengaged until the unit returns to a normal state of operation. A failure is defined as a condition which
causes the unit to stop running.
A SPDT set of contacts are provided to the user. These three contact connections are known as "Common",
"Normally Open" and "Normally Closed", and are electrically isolated to the relay. The contacts are rated for
voltages up to 30V DC /AC with a maximum current of 3A.