Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

Virtual Modem Initialization Commands
362 IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0
AT&Z1 Set command allows the user to store an IP
address and port number or phone number to
use when making a connection. The user will
issue an ATDS1 to cause the IOLAN to initiate
the connection.
AT&Sn Sets the behavior of IOLAN’s DTR signal.
(DSR from a DCE perspective)
n=0, DTR signal always high.
(default)
n=2, DTR signal acts as DCD.
n=3, DTR signal acts as RI.
AT&Rn Sets the behavior of IOLAN’s RTS signal. (CTS
from a DCE perspective)
If line is configured for hardware flow control,
the RTS is used for this purpose and the setting
of this command is ignored.
n=0, RTS always high. (default).
n=3, RTS signal acts as DCD.
n=4, RTS signal acts as RI.
AT&Cn Sets the behaviour of the DCD signal. n=0, DCD always on.
n=1, DCD follows state of
connection (off when no
connection, on when TCP
connection exists). (default)
AT&F Sets the modes back to the factory defaults. This
is a hard-coded default configuration which
does not look at any user configuration.
ATS2 Sets the value of the S2 register. The S2 register
controls which character is used to enter
“command” mode. (this is the potential
replacement for the +++ (default) in front of the
ATH command).
This register will hold the hex value of the
“escape” character. Any value > 27 will disable
the ability to escape into “command” mode.
ATS12 Sets the value of the S12 register. The S12
register controls the minimum length of idle
time which must elapse between the receipt of
the escape character and the A (first character of
the ATH sequence). Units are 1/50th of a
second. The default is 50 = 1 second.
ATO (ATD with no phone number) Establishes a
connection using the IP and port specified in the
telephone number field.
ATDS1 Establishes a connection using the IP and port
(or phone number) specified in the
Phone
Number
field (stored by the AT&Z1 command).
Command Description Options