Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

I/O Channels
316 IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0
I/O Channels
Overview
When the DeviceManager is connected to an I/O model IOLAN, the I/O Status/Control option is
available. You can view the I/O status and manually control such options as clearing alarms, clearing
minimum/maximum values, resetting the channel(s), and activating/deactivating output.
The following buttons are available:
Reset Channel
Button
Clear Alarm
Button
Clear Latched
Input Button
Clear Minimum
Value Button
Clear Maximum
Value Button
Activate Output
Button
Deactivate Output
Button
Reset All Channels
Button
Refresh Button
Resets the highlighted channel (click on a channel to highlight it).
Clears the alarm. Note that if the condition that tripped the alarm still exists, the
alarm will not look like it’s cleared, but will reflect the appropriate alarm level
severity. Alarm Level 0 means that the alarm has not been triggered.
Clears the latched value.
Clears the minimum value.
Clears the maximum value.
Manually activates the channel output.
Manually deactivates the channel output.
Resets all the channels.
Resets the highlighted channel (click on a channel to highlight it).