Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

Management
306 IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0
Time Zone/Summer Time Tab Field Descriptions
You can configure an automatic summer time (daylight savings time) time change.
Configure the following parameters:
Time Zone Name The name of the time zone to be displayed during standard time.
Field Format: Maximum 4 characters and minimum 3 characters (do not use
angled brackets < >)
Time Zone Offset The offset from UTC for your local time zone.
Field Format: Hours hh (valid -12 to +14) and minutes mm (valid 0 to 59
minutes)
Summer Time
Name
The name of the configured summer time zone; this will be displayed during
the summer time setting. If this parameter is not set, then the summertime
feature will not work.
Field Format: Maximum 4 characters and minimum 3 characters (do not use
angled brackets < >)
Summer Time
Offset
The offset from standard time in minutes. Valid values are 0 to 180.
Range: 0-180
Default: 60
Summer Time
Mode
You can configure the summer time to take effect:
z None—No summer time change.
z Fixed—The summer time change goes into effect at the specified time
every year. For example, April 15 at 1:00 pm.
z Recurring—The summer time changes goes into effect every year at same
relative time. For example, on the third week in April on a Tuesday at 1:00
pm.
Default: None
Fixed Start Date Sets the exact date and time in which the IOLAN’s clock will change to
summer time (daylight saving time) hours.
Fixed End Date Sets the exact date and time in which the IOLAN’s clock will end summer time
hours and change to standard time.