Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

Channels
258 IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0
Digital Output
Overview
When the channel is set for digital output, either voltage is applied to the channel or the channel is
grounded. Note that the internal jumpers must match the software setting and must be set to Output
(by default, they are set to Input); see
Digital I/O Module on page 382 to find out how to set the
internal jumpers.
Functionality
The Digital output channels support three types of Digital output: sink (voltage), source (ground), and
sink and source (apply voltage or ground). For the output type, you can configure the following
options:
z You can choose to manually activate/deactivate the Digital output.
z You can choose to manually activate/deactivate the Digital output and then specify that the
Digital output will either pulse (you get to specify the active and inactive pulse times)
continuously or for a specified number of pulse counts.
z You can choose to manually activate/deactivate the Digital output and then specify a delay before
the output goes from inactive to active or active to inactive.
z You can also specify a failsafe action that can either activate or inactivate the Digital output
when the failsafe timer is triggered (see
Failsafe Timer Functionality on page 249 for more
information).
In an industrial freezer warehouse, the IOLAN D4 is used to monitor the freezer doors. When one of
the industrial freezer doors are left open for more than five minutes, the Monitoring Application
(using the Perle API) starts the Digital output sink, causing the strobe light on top of the offending
freezer to activate.
IOLAN
perle
Monitoring
Application
Network
Industrial
Freezers
Digital I/O
Input
Input
Output
Output
D4