Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

Serial Port Profiles
134 IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0
Advanced Tab Field Descriptions
The TruePort Advanced tab determines how the TruePort connection is initiated and then sets up the
appropriate connection parameters.
Configure the following parameters:
Signals high
when...
This option has the following impact based on the state of the TruePort
connection:
z TruePort Lite Mode—When enabled, the EIA-232 signals remain active
before, during, and after the TruePort connection is established. When
disabled, the EIA-232 signals remain inactive when there is no TruePort
connection and active when there is a TruePort connection.
z TruePort Full Mode—When enabled, the EIA-232 signals remain active
before and after the TruePort connection and the TruePort client will
control the state of the signals during the established TruePort connection.
When disabled, the EIA-232 signals remain inactive before and after the
TruePort connection and the TruePort client will control the state of the
signals during the established TruePort connection.
Default: Enabled
Enable Message of
the Day (MOTD)
Enables/disables the display of the message of the day.
Default: Disabled
Enable TCP
Keepalive
Enables a per-connection TCP keepalive feature. After the configured number
of seconds, the connection will send a gratuitous ACK to the network peer,
thus either ensuring the connection stays active OR causing a dropped
connection condition to be recognized.
This parameter needs to be used in conjunction with
Monitor Connection
Status Interval
parameter found in the Serial, Advanced, Advanced Settings
tab. The interval specifies the inactivity period before "testing" the connection.
Default: Disabled