Server User Manual
Table Of Contents
- SDS/SCS/STS/MDC User’s Guide
- Table of Contents
- Preface
- Introduction
- Hardware and Connectivity
- Configuration Methods
- Getting Started
- Using DeviceManager and WebManager
- Network Settings
- Configuring Serial Ports
- Introduction
- Serial Ports
- Serial Port Profiles
- Common Tabs
- Console Management Profile
- TruePort Profile
- TCP Sockets Profile
- UDP Sockets Profile
- Terminal Profile
- User Service Settings
- Printer Profile
- Serial Tunneling Profile
- Virtual Modem Profile
- Control Signal I/O Profile
- Modbus Gateway Profile
- Power Management Profile
- Remote Access (PPP) Profile
- Remote Access (SLIP) Profile
- Custom Application Profile
- Port Buffering
- Advanced
- Configuring Users
- Configuring Security
- Configuring I/O Interfaces
- Configuring Clustering
- Configuring the Option Card
- Configuring the System
- Controlling the RPS, I/O Channels, and IPsec Tunnels
- System Administration
- Introduction
- Managing Configuration Files
- Downloading IOLAN Firmware
- Calibrating I/O
- Setting the IOLAN’s Date and Time
- Rebooting the IOLAN
- Resetting the IOLAN to Factory Defaults
- Resetting the SecurID Node Secret
- Language Support
- Downloading Terminal Definitions
- Resetting Configuration Parameters
- Lost Admin Password
- Applications
- RADIUS and TACACS+
- SSL/TLS Ciphers
- Virtual Modem AT Commands
- Pinouts and Cabling Diagrams
- Setting Jumpers
- I/O Wiring Diagrams
- Utilities
- Accessories
- Troubleshooting
- Introduction
- Hardware Troubleshooting
- Communication Issues
- DeviceManager Problems
- Host Problems
- RADIUS Authentication Problems
- Login Problems
- Problems with Terminals
- Unknown IP Address
- DHCP/BOOTP Problems
- Callback Problems
- Language Problems
- Modem Problems
- PPP Problems
- Printing Problems
- Long Reboot Cycle
- SSL/TLS
- I/O Models
- IPv6 Issues
- Contacting Technical Support
- Glossary
- Index

117
Serial Port Profiles
Hardware Tab Field Descriptions
The Hardware tab configures all the serial port hardware connection information. The window below
shows an SDS1 model; your
Hardware tab might display a subset of the parameters described,
depending on the IOLAN model and supported hardware.
Configure the following parameters:
Serial Interface Specifies the type of serial line that is being used with the IOLAN.
Data Options: EIA-232, EIA-422, or EIA-485.
SCS/STS/MDC models support only EIA-232.
Default: EIA-232
Speed Specifies the baud rate of the serial line; keep in mind that speed is affected by
the length of the cable. You can also specify a custom baud rate. When you
enter a custom baud rate, the IOLAN will calculate the closest baud rate
available to the hardware. The exact baud rate calculated can be viewed in the
Serial Ports statistics.
Range: 50-230400, custom supports 50-1843200
Default: 9600
Data Bits Specifies the number of bits in a transmitted character.
Default: 8
Parity Specifies the type of parity being used for the data communication on the serial
port. If you want to force a parity type, you can specify
Mark for 1or Space for
0.
Data Options: Even, Odd, Mark, Space, None
Default: None
Stop Bits Specifies the number of stop bits that follow a byte.
Data Options: 1,1.5, 2. 1.5 is only available on the 1-port and 2-port models,
but not on the modem line (Serial Port 2) of the SDS1M model.
Default: 1