Installation Manual
N40475 Chapter 13
Page 71
Lubricating system
Recommended lubricating oil ...............................................API / CH4 / CI-4
Sump capacity maximum ................................................. 15 litres (3.3 gallons)
Maximum operational angle .......................20
O
nose up. Heel 25
O
constant, 35
O
intermittent
Oil pressure in operating ............................................................. 3.6 bar
speed range (steady state)
Electrical system
Alternator .................................................. Insulated return 12 Volt-100 amp or 24 Volt-55 amp
Starter type ...................................................................................4.0Kw
Number of teeth in ywheel ............................................................126
Number of teeth on starter...............................................................10
Cold start limits
Minimum cold start temperature (with aid) .............................. -15
O
C (5
O
F)