Fuel system
Recommended fuel .............................................. DIN E 590 DERV (class A-F & 0-4)
BS2869 Class A2 (Off highway, gas oil, red diesel)
ASTM D975-91 Class 1-1DA & Class 2-2DA
JIS K2204 (1997) Grades 1, 2, 3 & Special grade 3
Fuel injection pump ..................................................................... CR200
Fuel lift pump ............................................................................... manual
Fuel feed pressure (static) .............................................. 0.3 to 0.6 bar (5 to 8psi)
Governor type ...............................................................................A4:E2
Pipe size:
• Supply - outside diameter ................................................... 10mm (0.394”)
• Supply - bore ...................................................................... 8.4mm (0.331”)
• Return - outside diameter .................................................... 10mm (0.394”)
• Return - bore ...................................................................... 8.4mm (0.331”)
Maximum lift pump lift ........................................1.8m (6ft) to bottom of tank suction pipe.
Maximum fuel lift pump .................................... 127mm (5 inches) Hg depression at inlet.
Fuel consumption at full .................62 l/hr ..................51.9 l/hr ............... 44.74 l/hr ............... 37.03 l/hr
Air intake
Combustion airow .................... 15.7m
3
/min .......... 15.04m
3
/min ......... 14.6m
3
/min .......... 12.33m
3
/min
Maximum engine compartment ................................................... 60
O
C.
air temperature.
Maximum air temperature at......................................................... 52
O
C.
engine inlet
Ventilation - maximum engine ..........................................125mm WG (5” WG).
room depression
Minimum cross section ..........
968cm
2
for hot climates ..806cm
2
for hot climates ...697cm
2
for hot climates .. 613cm
2
for hot climates
of air duct (per engine). ........
484cm
2
for temp climates .403cm
2
for temp climates . 348cm
2
for temp climates 306cm2 for temp climates
Exhaust
Exhaust gas ow ....................... 45.9m
3
/min ........... 36.8m
3
/min ......... 27.13m
3
/min ......... 22.97m
3
/min
Maximum restriction measured ....................................................15kPa
within (305mm) 12” of turbocharger outlet .
Recommended pipe bore (wet exhaust) ................................ 127mm (5.0”)
Recommended pipe bore (dry) ................................................ 69mm (2.7”)
Minimum rise from sea level to ............................................... 203mm (8.0”)
exhaust outlet centre-line