Troubleshooting

(Table 71, contd)
Troubleshooting Test Steps
Values Results
11. Use the Electronic Service Tool to Reset the IVS Thresh-
old Limits
The electronic service tool can be used to change the Idle Valida-
tion Min OFF Threshold and the Idle Validation Max ON Thresh-
old in order to suit the type of throttle that is installed. The limits
are shown in the Throttle Configuration screen which is located
in the Service menu.
A. Refer to Test Step 8 and record the raw value of the throttle sig-
nal when the idle validation switch changes from the CLOSED po-
sition to the OPEN position.
Note: The default value for the Idle Validation Min OFF Thresh-
old is 21%. The lowest value that should be set is 5%. The de-
fault value for the Idle Validation Max ON Threshold is 25%. The
maximum value that is expected is 28%.
B. Set the Idle Validation Min OFF Threshold to 3% below the
raw value that was previously recorded.
C. Set the Idle Validation Max ON Threshold to 3% above the
raw value.
D. Enter the new threshold limits into the electronic service tool.
Click Submit on the electronic service tool screen.
E. Turn the keyswitch to the OFF position and wait at least 5 sec-
onds. Turn the keyswitch to the ON position.
F. Repeat Test Step 8. Check that the IVS operates within the
newly set threshold limits.
Fault cleared Result: The fault is cleared after programming
the new calculated values.
Return the engine to service.
Result: The fault is not cleared.
Contact the Dealer Solution Network (DSN).
Complete the procedure in the order in which the
steps are listed.
If the procedure did not correct the issue, Contact the
Dealer Solution Network (DSN).