SPECIFICATIONS

i05239446
Turbocharger
Illustration 20 g02626265
Typical example
(1) Actuator
The test pressure for the wastegate actuator
. . . . . . . . . . . . . . . . . . . . . 170 kPa ((24.6568 psi))
The movement for the rod actuator
. . . . . . . . . . . . . . . . . . . . . . 10 mm ((0.3937 inch))
Illustration 21 g02626267
Typical example
(2) Tighten the studs to the following torque.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 N·m ((11 lb ft))
(3) Tighten the nuts to the following torque.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 N·m ((18 lb ft))
Illustration 22 g02626269
Typical example
(4) Tighten the bolt to the following torque.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 N·m ((16 lb ft))
(5) Tighten the bolts to the following torque.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 N·m ((18 lb ft))
14 UENR0622-02
Specifications Section
This document has been printed from SPI2. NOT FOR RESALE