Operation and maintenance manual

2. If necessary, remove breather pipes on cover (6).
Remove nuts (7) and remove cover (6) from
housing (1).
3. Remove circlip (4) and remove the breather
element (3) and discard.
4. Remove the O ring seal (5) from the cover.
Install the Breather Element
Ensure that all the components are clean and free
from damage.
Illustration 58 g02827300
Typical example
(A) Diameter
(B) Diameter
1. Install a new O ring seal (5) onto the cover (6).
Note: The breather element must have the correct
orientation before installation. Diameter (A) is visibly
larger than diameter (B).
2. Install diameter (A) of the breather element (3)
onto the shaft (2). When correctly installed the part
number of the breather element will be visible.
3. Install circlip (4) and cover (6). Install nuts (7) and
tighten to 25 N·m (18 lb ft). If necessary, install
breather pipes to cover.
4. Install the guard, refer to OEM.
i02323089
Engine Mounts - Inspect
Note: The engine mounts may not have been
supplied by Perkins. Refer to the OEM information for
further information on the engine mounts and the
correct bolt torque.
Inspect the engine mounts for deterioration and for
correct bolt torque. Engine vibration can be caused
by the following conditions:
Incorrect mounting of the engine
Deterioration of the engine mounts
Loose engine mounts
Any engine mount that shows deterioration should be
replaced. Refer to the OEM information for the
recommended torques.
i04728471
Engine Oil Level - Check
Hot oil and hot components can cause personal
injury. Do not allow hot oil or hot components to
contact the skin.
Illustration 59 g02829378
Typical example
NOTICE
Perform this maintenance with the engine stopped.
SEBU8726-03
99
Maintenance Section
Engine Mounts - Inspect
This document has been printed from SPI2. NOT FOR RESALE