Operation and maintenance manual
Table 2
Warning
Indicator
Shutdown
Indicator
Lamp State Description of the Indication Engine Status Operator Action
On On Indicator Check When the keyswitch is moved to
the ON position, the lamps will illu-
minate for 2 seconds and the lamps
will then go off.
During indicator check, the after-
treatment indicators will also be
checked.
The keyswitch is in the ON
position but the engine has
not yet been cranked.
If any of the indicators
will not illuminate during
indicator check, the
fault must be investi-
gated immediately.
If any Indicators stay il-
luminated or flash, the
fault must be investi-
gated immediately.
Off Off No Faults With the engine in operation, there
are no active warnings, diagnostic
codes, or event codes.
The engine is operating with
no detected faults.
None
Level 1
On Solid Off Warning Level 1 warning The engine is operating nor-
mally but there is one or
more faults with the elec-
tronic management system
for the engine.
As soon as possible the
fault should be
investigated.
Level 2
Flashing Off Warning Level 2 warning The engine continues to be
operated, but there are active
diagnostic, or event codes
active.
Derate to engine power may
be applied.
Stop the engine.
Investigate the code.
Level 3
Flashing On solid Warning Level 3 warning
If both the warning lamp and the
shutdown lamp are in operation,
this issue indicates one of the fol-
lowing conditions.
1. One or more of the shutdown
values for the engine protection
strategy has been exceeded.
2. A serious active diagnostic code
has been detected.
3. After a short time period, the en-
gine may shut down.
The engine continues to be
operated, but the level of im-
portance of the warning has
increased.
The engine will automatically
shut down.
If shut down is not enabled,
the engine could be dam-
aged if continued to be
operated.
Stop the engine
immediately.
Investigate the fault
i04348489
Overspeed
• ECM Electronic Control Module
• RPM Revolutions Per Minute
An overspeed is detected by the speed/timing
sensors.
The default overspeed is set at 2800. The ECM will
cut the power to the electronic unit injectors, until the
rpm drops below the overspeed setting. A diagnostic
fault code will be logged into the ECM memory and a
warning lamp will indicate a diagnostic fault code.
Some application may have a display panel in order
to alert the operator.
SEBU8726-03
37
Operation Section
Overspeed
This document has been printed from SPI2. NOT FOR RESALE