Disassembly and assembly
Illustration 163 g02663458
Illustration 164 g02663598
2. Clean the seal surface on the cylinder block.
3. Install a new seal (3) to the water pump (2).
4. Install the water pump (2) to the cylinder block.
Note: Ensure that the water pump is correctly
orientated.
5. Install bolts (1) to the water pump. Tighten the
bolts to a torque of 25 N·m (221 lb in).
6. Fill the cooling system with coolant. Refer to
Operation and Maintenance Manual, “Cooling
System Coolant - Change” for the correct
procedure.
End By:
a. Install the alternator belt. Refer to Disassembly
and Assembly, “Alternator Belt - Remove and
Install” for the correct procedure.
i05270793
Water Temperature Regulator -
Remove and Install
Removal Procedure
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened
component life.
NOTICE
Care must be taken to ensure that fluids are con-
tained during performance of inspection, mainte-
nance, testing, adjusting and repair of the product.
Be prepared to collect the fluid with suitable contain-
ers before opening any compartment or disassem-
bling any component containing fluids.
Dispose of all fluids according to local regulations
and mandates.
1. Drain the coolant from the cooling system to a
level below the water temperature regulator, into a
suitable container for storage or for disposal. Refer
to Operation and Maintenance Manual, “Cooling
System Coolant - Change” for the correct draining
procedure.
2. Remove the wastegate regulator valve. Refer to
Disassembly and Assembly, “Wastegate Solenoid
- Remove and Install” for the correct procedure.
96 UENR0624-03
Disassembly and Assembly Section
This document has been printed from SPI2. NOT FOR RESALE