Disassembly and assembly

Illustration 345 g02837996
1. Before installing glow plugs (5), ensure that the
glow plugs are operating correctly. Refer to
Troubleshooting, “Glow Plug Starting Aid - Test”
“Check the Operation of the Glow Plugs” for the
correct procedure.
2. Ensure that the threads of the glow plugs are clean
and free from damage. Replace any damaged
glow plugs.
3. Install glow plugs (2) into the cylinder head .
Tighten the glow plugs to a torque of 9 N·m
(80 lb in).
4. Connect wiring harness (1) to glow plugs (2).
5. Turn the battery disconnect switch to the ON
position.
6. If necessary, install the Exhaust Gas Recirculation
(EGR) valve. Refer to Disassembly and Assembly,
Exhaust Gas Recirculation Valve - Remove and
Install” for the correct procedure.
End By:
a. Install the combined inlet manifold temperature
and pressure sensor. Refer to Disassembly
and Assembly, “Inlet Manifold Temperature
and Pressure Sensor - Remove and Install” for
the correct procedure.
i05284613
Alternator Belt - Remove and
Install
Removal Procedure
1. If the engine has guards, remove the guards. Refer
to the Original Equipment Manufacture (OEM) for
the correct procedure.
Illustration 346 g02553437
Typical example
2. Loosen locking nut (2) and alternator tensioning
bolt (1).
3. Loosen nut and bolt (4).
4. Loosen bolt (3) for adjusting bracket (5).
5. Remove alternator belt (6).
Note: Note the routing of the alternator belt before
removal.
UENR0624-03 191
Disassembly and Assembly Section
This document has been printed from SPI2. NOT FOR RESALE