Disassembly and assembly

d. Install connectors (2) to fuel priming pump (4).
e. Install plugs (5) to fuel priming pump (4).
f. Tighten the plugs and the connectors to a
torque of 20 N·m (14 lb ft).
3. Position fuel priming pump (4) on the mounting
bracket. Install bolts (7) to the fuel priming pump .
Tighten the bolts to a torque of 44 N·m (32 lb ft).
4. Remove the plugs from the plastic tube
assemblies. Remove the caps from the
connectors.
5. Connect plastic tube assemblies (1) to connectors
(2).
Note: Ensure that the plastic tube assemblies are
installed in the original positions.
6. Install a new primary filter (6) to fuel priming pump
(4). Refer to Operation and Maintenance Manual,
“Fuel System Primary Filter (Water Separator)
Element - Replace”.
7. Turn the fuel supply to the ON position.
8. Prime the fuel system. Refer to Operation and
Maintenance Manual, “Fuel System - Prime”.
i05268256
Flow Control Valve - Remove
and Install
Removal Procedure
Table 2
Required Tools
Tool Part Number
Part Description Qty
A T412504
Capping Kit
1
Contact with high pressure fuel may cause fluid
penetration and burn hazards. High pressure fuel
spray may cause a fire hazard. Failure to follow
these inspection, maintenance and service in-
structions may cause personal injury or death.
NOTICE
Ensure that all adjustments and repairs that are
carried out to the fuel system are performed by
authorized personnel that have the correct
training.
Before beginning ANY work on the fuel system,
refer to Operation and Maintenance Manual,
“General Hazard Information and High Pressure
Fuel Lines” for safety information.
Refer to System Operation, Testing and Adjust-
ing, “Cleanliness of Fuel System Components”
for detailed information on the standards of
cleanliness that must be observed during ALL
work on the fuel system.
1. Turn the fuel supply to the OFF position.
2. Turn the battery disconnect switch to the OFF
position.
Illustration 18 g02986577
3. Clean the area around flow control valve (2) and
fuel injection pump. Ensure that the area is free
from contamination before beginning disassembly.
4. Disconnect harness assembly (3) from flow control
valve (2).
5. Make temporary marks on the flow control valve
and the fuel injection pump for installation
purpose.
6. Remove Torx heads screws (1) from the flow
control valve.
7. Remove flow control valve (2) from the fuel
injection pump.
12 UENR0624-03
Disassembly and Assembly Section
This document has been printed from SPI2. NOT FOR RESALE