• The bend radius or the coil should be no less than
51 mm (2 inch) at any point
• The cables should avoid sharp metal edges and
are not restricted.
Connect the coax cables to the antenna connections
on the Clean Emissions Module (CEM). Tighten the
connections to a torque of 1.2 ± 0.2 N·m
(11 ± 1.8 lb in).
Nitrogen Oxide Sensor for 1206F-
E70TA, and 1206F-E70TTA Engines
Note: There are two NOx sensors. One sensor
should be installed in the Clean Emissions Module
(CEM). The other sensor should be installed into the
exhaust tail pipe at a suitable position.
Note: The NOx sensor that should be installed in
the CEM has a black cable. The NOx sensor that
should be installed in the exhaust tail pipe has a
gray cable. If the sensing unit is installed in the
wrong location, a diagnostic code will be come
active.
Certain transportation, storage, and handling
recommendations are listed below:
• Shipping boxes should be transported and stored
in a closed condition. Store the sensors in the
original, closed shipping box until the sensor is
ready for use. The maximum storage time in
production packaging boxes is 18 months after
production. The maximum storage time in spare
part packaging is 2 years after production.
• Sensors should be stored in a temperature range
of -40° C to 105° C.
• Handle and store the NOx sensor in a clean, dry
area, free of contamination, and inclement
weather.
• Avoid temperature shock when opening a shipping
box. Avoid a temperature difference of more than
±5° C between the sensors and the environment.
Allow at least 4 hours for the sensors to reach
ambient temperature before opening the box to
avoid condensation on the parts.
• Do not open the shipping box with a knife that will
deeply penetrate the box. The knife may damage
the sensors or sensor cables.
• Do not remove the sensing unit protective cap until
the sensor is ready for installation into the exhaust
system.
• Avoid impact to the NOx sensor, dropping the
sensor could cause permanent damage. If the
sensor has had an impact, discard the sensor.
• Do not paint any part of the sensing unit.
• Do not clean any part of the sensor with chemical
cleaners.
Illustration 61 g03393625
Typical example
1. Remove cap (1) from Clean Emissions Module
(CEM) (2). Ensure that the internal threads are
clean and free from debris.