Fuel Cooler for 1206F-E70TA, and
1206F-E70TTA, 1204F-E44TA,
1204F-E44TTA Engines
The fuel cooler can be supplied loose.
Illustration 49 g03179997
Typical example
Install the fuel cooler (1) to the application.
Install the nuts (3) finger tight. Tighten the nuts to a
torque of 35 ± 5 N·m (26 ± 4 lb ft).
Note: Ensure that the 30 mm (1.18 inch) hexagonal
connection (2) is secure when the nuts (3) are
tightened.
Fuel Filter (In-Line) for 1206F-
E70TA, and 1206F-E70TTA, 1204F-
E44TA, 1204F-E44TTA Engines
The fuel filter (In line) can be supplied loose.
Illustration 50 g03178796
Typical example
The fuel filter (In line) has an inlet connection of
12.7 mm (0.5 inch) (2). The fuel filter (In line) has an
outlet connection of 10 mm (0.39 inch) (1).
Note: Ensure that the flow of fuel through the fuel
filter (In line) follows the direction as shown in
illustration 50.
Fuel Priming Pump (Electric Fuel
Lift Pump (EFLP)) for 1206F-E70TA,
and 1206F-E70TTA, 1204F-E44TA,
1204F-E44TTA Engines
The fuel priming pump can be supplied loose.
Illustration 51 g03691471
Typical example
This document has been printed from SPI2. NOT FOR RESALE