User Manual
18
• The strap size should have a width of 30 mm
(1.18 inch) and a thickness of 1.5 mm (0.06 inch).
• The strap material should be stainless steel with
rubber backing.
• The bolt size should be M10 by 1.5 with a bolt
length of 90 mm (3.54 inch).
The strap pre-load should be a nominal 2.5 kN
(562 lb). The maximum strap pre-load should be 4 kN
(900 lb).
Tighten nuts to an initial torque
. . . . . . . . . . . . . . . . . . . . . . . 8 ± 2 N·m ((71 ± 18 lb in))
Tighten nuts to a final torque
. . . . . . . . . . . . . . . . . . . . . . . 11 ± 1 N·m ((97 ± 9 lb in))
Type 2 DEF Tank
Type 2 DEF tanks are supplied by the Original
Equipment Manufacturer (OEM). Type 2 DEF tanks
are not supplied by the engine manufacturer.
The manifold (DEF) is supplied by the engine
manufacturer.
The manifold (DEF) must be installed to the DEF tank
as a sub assembly process.
Contact the applications engineer for the engine
manufacturer if type 2 DEF tank and associated
components are to be installed.
Diesel Exhaust Fluid Lines
The diesel exhaust fluid lines must be installed with
the following conditions:
• Be routed as direct as possible with no excessive
dips or sags
• Be routed to avoid abrasion and overheating
• Be adequately supported and not impose stress on
the connector. The maximum clipping details are
detailed in table 4 .
• Must fall within the length guidelines in table 5 .
• Allow for relative movement between the two
components, DEF tank to DEF pump, DEF pump
to DEF injector
• Do not exceed the minimum bend radii. Refer to
table 6 for more information.
Table 4
Maximum clipping distances
Connection to Clip Clip to Clip
Electrical Cable
150 mm (6 inch)
150 to 300 mm
(6 to 12 inch)
150 mm (6 inch)
Table 5
DEF Lines
Length
Min Max
Suction (DEF tank to pump)
1000 mm
(39.4 inch)
2000 mm
(78.7 inch)
Pressure (pump to DEF injector)
1500 mm
(59 inch)
4000 mm
(157.5 inch)
Return (DEF injector to pump)
1500 mm
(59 inch)
4500 mm
(177 inch)
Note: For a 12 VDC system, the total length of the
three diesel exhaust fluid lines must not exceed
9500 mm (374 inch).
Note: For a 24 VDC system, the total length of the
three diesel exhaust fluid lines must not exceed
10000 mm (394 inch).
Table 6
Minimum Bend Radius
Diesel exhaust fluid lines
56 mm (2.2 inch)
Harness
10 mm (0.39 inch)
There are three DEF lines as shown in the following
table:
Table 7
DEF Line Fitting 1 Fitting 2
DEF tank outlet to
PEU inlet
DEF Tank Outlet =
3/8 inch
PEU Inlet = 3/8
inch
PEU outlet to DEF
injector inlet
PEU Outlet = 5/16
inch
DEF Injector Inlet =
5/16 inch
DEF injector return
to DEF tank
DEF Injector Re-
turn = 3/8 inch
DEF Tank Return =
5/16 inch