Tighten the M8 bolts to the following torque.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 N·m ((11 lb ft))
Illustration 23 g03412391
Typical example
The DEF pump assembly should be supported by a
support bracket (4).
Tighten the fasteners (3) that secure the bracket (4)
to the following torque.
. . . . . . . . . . . . . . . . . . . . . 12 ± 3 N·m ((106 ± 27 lb in))
DEF Tank with separate Pump Electronic Unit
(PEU)
Note: The DEF tank should be mounted to the
application using the installation guidelines described
in “Type 1 DEF Tank” or “Type 2 DEF Tank”.
Illustration 24 g03418031
Typical example
Note: If the PEU is to be mounted on isolating
mounts, a rigid metal bracket should be used.
Contact the applications engineer for the engine
manufacturer for more information.
M6 fasteners are recommended to secure PEU to the
application.
Tighten the fasteners (1) that secure the PEU (2) to
the following torque. . . . 12 ± 3 N·m ((106 ± 27 lb in))