Operation and maintenance manual

SEBU8601-01 63
Operation Section
Engine Operation
Regeneration Switch
Note: The MIDDLE position of the regeneration
switch is the default position for automatic modes
of regeneration.
Note: Some OEMs may use other means of
activating a forced regeneration such as touch screen
interfaces.
Force R egeneration Press in the top
of the switch for 2 seconds in order to
begin regeneration. An indicator light on
the switch will become active showing that the
regeneration is active. The HEST lamp will become
active showing that the regeneration is active. The
high exhaust temperature indicator will deactivate
after regeneration is completed or the regeneration
has been disabled.
Disable R egeneration Press in the
bottom of the switch for 2 seconds in order
to disable regeneration. An indicator light on
the switch will become active. The disable indicator
lamp will illuminate. The indicator will deactivate after
the disable regeneration is completed.
Note: To re-enable the regeneration, cycle the engine
start switch key or press and hold down the force
regeneration switch for 2 seconds.
Note: If the engine start switch key is cycled while
the regeneration system is disabled via the disable
regeneration switch, press and hold the disable
regeneration switch for 2 seconds to reinitiate the
disable regeneration.
Soot Level Monitoring and Indicator
Lamps
During the normal working cycle of the engine the
ECM will control when the regeneration will occur.
Operation of the engine is not recommended with
theamberwarninglightashing, or the red lamp
illuminated. Operation of the engine at this level
could damage the DPF.